EXPLORE HOT AND COLD AISLE CONTAINMENT FOR YOUR DATA CENTER

Explosion-proof type for cold aisle of agent data center

Explosion-proof type for cold aisle of agent data center

Lightweight, durable, impact resistant, and thermal insulating, polycarbonate twinwall enables secure, easily scalable, and thermally regulated hot and cold aisle containment systems for data storage and processing. Where Cold Aisles are part of the room being protected, we try to include nozzles in the aisles wherever possible. Hot aisle and cold aisle containment are foundational concepts in data center design. It involves the use of physical barriers or enclosure at the end of server aisles to separate hot and cold airflows. However, without a physical barrier, you can still have wrap-around and bypass air, which can result in unacceptably high air temperat urr DCM cabinets with 4' or 6' aisles, and requires a uniform row.

Read More
Cold Aisle Configuration Scheme for Data Center

Cold Aisle Configuration Scheme for Data Center

Cold aisle containment (CAC) is a proven data center cooling strategy that creates physical barriers around cold air supply zones, preventing contamination from hot exhaust air and eliminating the energy-wasting effects of air mixing. Hot aisle and cold aisle containment are foundational concepts in data center design. While these concepts are not new, their successful implementation requires detailed planning, precise engineering, and thorough analysis to deliver maximum efficiency.

Read More
What is a hot aisle in a computer room

What is a hot aisle in a computer room

The hot aisle /cold aisle data center layout was originated by IBM in 1992 and it is one of the oldest ways to save energy in the data center. Assuming a computer room is configured in such a way that either is an option, hot aisle containment may be seen as the better option because it has some thermal efficiency and ride-through advantages. However, because every computer room is unique, there is no one definitive solution. The HAC system directs the upward airflow to an AC return system such as a drop-ceiling void. The system simply aligns server fronts (air intakes) toward a shared cold aisle, and backs (exhausts) toward a shared hot aisle. Cold Aisle: Rows of racks face each other, forming a corridor where cool air is directed.

Read More
What should be used to seal the cold aisle in the computer room

What should be used to seal the cold aisle in the computer room

The Cool Shield AirStrip is an expanding foam tape designed to prevent unwanted air loss from gaps in contained aisles, server rack rows and data center infrastructure. Strips can be used above or below containment panels, next to rack rails, under server cabinets or in gaps in raised flooring. While advanced cooling systems like chilled water plants and CRAH units play a major role, one of the most effective strategies is much simpler: controlling how air moves through the data hall. This method raises the temperature of the air returning to a Computer Room Air Con itioner (CRAC) unit, which allows the unit to operate more eficiently. By sealing out moisture, the total available cooling can be more effectively used to cool the computer servers' heat load, which is 100% sensible (no moisture content).

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales)

+27 21 850 1234

🇪🇺

EU Manufacturing Center

+34 936 214 587

📍

Headquarters (Spain)

Avinguda de la Garriga 23, 08830 Sant Boi de Llobregat, Barcelona, Spain