GENERATOR ROOM VENTILATION REQUIREMENTS

Power generator room cabinet

Power generator room cabinet

The space requirements for standby and emergency power systems do not rank at the top of an architect's design list. Consequently, service personnel can find themselves in tight quarters when these power s.

Read More
Asynchronous Generator Relay Protection

Asynchronous Generator Relay Protection

Generator loss-of-excitation protection serves as a critical defense against generator excitation current failure caused by excitation system faults. As vital protection against system oscillations, terminal equipment damage, and reverse flow of reactive power during. Inverse Time Neutral Overcurrent System Backup Protection for Phase Faults 21 – Phase Distance 51V – Voltage R/C Inverse Time Phase Overcurrent System Backup Protection for Ground Faults 51G from ground CT on GSU high side wye -grounded leg TOC – Theory (continued) 4 32 – Reverse Power 46 –. Generators are designed to run at a high load factor for a large number of years and permit certain incidences of abnormal working conditions. Our automatic generation control (AGC) and synchrophasor technology give system operators unprecedented diagnostic and control capabilities to maximize power output, stability, efficiency, and reliability.

Read More
What should be used to seal the cold aisle in the computer room

What should be used to seal the cold aisle in the computer room

The Cool Shield AirStrip is an expanding foam tape designed to prevent unwanted air loss from gaps in contained aisles, server rack rows and data center infrastructure. Strips can be used above or below containment panels, next to rack rails, under server cabinets or in gaps in raised flooring. While advanced cooling systems like chilled water plants and CRAH units play a major role, one of the most effective strategies is much simpler: controlling how air moves through the data hall. This method raises the temperature of the air returning to a Computer Room Air Con itioner (CRAC) unit, which allows the unit to operate more eficiently. By sealing out moisture, the total available cooling can be more effectively used to cool the computer servers' heat load, which is 100% sensible (no moisture content).

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales)

+27 21 850 1234

🇪🇺

EU Manufacturing Center

+34 936 214 587

📍

Headquarters (Spain)

Avinguda de la Garriga 23, 08830 Sant Boi de Llobregat, Barcelona, Spain