SUBSTATION SHIELDING METHODS FOR LIGHTNING STRIKES

Outdoor distribution boxes must be protected against lightning strikes

Outdoor distribution boxes must be protected against lightning strikes

Type 1 SPDs should be installed at the service entrance, while Type 2 SPDs provide protection at distribution levels. Complete protection can be achieved only if power lines, data and signal lines are all protected using a surge protection device (SPD). OBO can offer the right selection of products, depending on the application and scope of protection. NEC (National Electrical Code) Article 314 provides strict requirements for these installations, and for good reason.

Read More
The transformer substation needs to be double grounded

The transformer substation needs to be double grounded

When there are two or more graded insulation transformers running in parallel in the substation, only one part of the transformer neutral point is considered to be grounded, while the other part of the transformer neutral point is grounded through the gap to. This is important to understand, because transformers will, in most cases, require a bonded connection to ground to be considered properly grounded per NEC Article 250. As we wrap up this series, this article outlines the purpose of substation grounding, the IEE Std 80 design, and best-practice field testing. A properly engineered ground grid limits hazardous voltage gradients during faults, provides. Transformer neutral grounding refers to the intentional connection of a transformer's neutral point—typically on the secondary winding—to ground.

Read More
Principle of Substation Relay Protection

Principle of Substation Relay Protection

Differential Relay: Compares currents at two points; operates when there is a difference (used in transformers and generators). IEEE/IAS/I&CPSD Protection & Coordination WG Chair Jacobs Canada, Calgary, AB rasheek. com IEEE Southern Alberta Section PES/IAS Joint Chapter Technical Seminar - November 2016 Protective Relays - Technical Seminar Nov 2016 - Copyright: IEEE 2 Abstract: Protective relays and devices. Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Based on Operating Principle Electromechanical Relays: Work using moving parts and electromagnetic forces (traditional relays). Long term cost reduction (TCO) for trainings and maintenance by reduce variety of relays A fast and selective arc fault mitigation for air-insulated LV & MV switchgear and Relion protection and control relays and sensor technology protect staff and plant facilities for many years.

Read More
What is the busbar in a high-voltage substation

What is the busbar in a high-voltage substation

In , a busbar (also bus bar) is a metallic strip or bar, typically housed inside,, and for local high current power distribution, transmission, or switching substations. Here, we provide an overview of common substation busbar configurations—Single Bus, Main and Transfer, Double Breaker/Double Bus, Ring Bus/Ring Main, and Breaker and a Half. Designing a substation involves not only the visible equipment and ratings but also the less apparent factors—operational. When a number of generators or feeders operating at the same voltage have to be directly connected electrically, bus-bars are used as the common electrical component.

Read More
Cable tray shielding

Cable tray shielding

Designed to protect power and equipment cables from the effects of elevated levels of radiant heat. Electrical systems generate electromagnetic waves, which can disrupt signals in unprotected cables. G-iron ® shielding channels is an innovative solution for the magnetic shielding of electrical cables and cable routing systems, designed to ensure efficiency, ease of installation and cost-effectiveness. When common mode current is generated through a copper conductor, EMI is created naturally by the copper's electrical. Features: Suitable for laying computer, communication, low-voltage, and control cables.

Read More