UNDERSTAND AND MITIGATE NETWORK LOOPS STP

How to check network loops on a core switch

How to check network loops on a core switch

You can test/check for network loops without disabling any ports by using Loop-Protect and setting the Receiver-Action to "no-disable". If one is detected, it will add an entry to the event log, but will not disable the port. A network loop occurs when redundant connections between switches cause data packets to endlessly circulate, suitable to broadcast storms, high CPU usage, and network congestion. Now at most of our sites we use Extreme, which has a handy feature called ELRP Extreme Loop Recovery Protocol, despite the name, this mechanism just detects loops, in the logs we can see, ok. The problem happening is that the core switch is disabling one uplink configured as a lag to one of the edge cabinets, when viewing the logs on the core, i found the below : LOOP DETECTION: VLAN 102, port lg110 detect, putting into err-disable state after disabling, reenabling the lag ports on the. There is also of course the way to get a hard proof by using Wireshark and a packet capture to check if one and the same frame is appearing with a.

Read More
Factors that make relay protection difficult to understand

Factors that make relay protection difficult to understand

Many important issues, such as coordination of settings, operating times, characteristics of relays, mutual coupling of lines, automatic reclosing, and use of communication channels, are examined. Long term cost reduction (TCO) for trainings and maintenance by reduce variety of relays A fast and selective arc fault mitigation for air-insulated LV & MV switchgear and Relion protection and control relays and sensor. Relay protection is the discipline of designing schemes that detect faults, coordinate relays, and isolate equipment without outages. In industrial power systems, Protection relays are expected to operate with high precision, isolating faults while keeping healthy parts of the network energized. This handbook covers the code of practice in protection circuitry including standard lead and device numbers, mode of connections at terminal strips, colour codes in multicore cables, dos and donts in execution.

Read More
How to understand the sensitivity of relay protection

How to understand the sensitivity of relay protection

The sensitivity of a relay is mentioned as a ratio of the minimum value of short circuit current to the minimum value of the quantity for the operation. Based on simple examples of the generator-transformer unit protection from symmetrical short circuits, it was shown that the sensitivity factor is not a sufficiently objective measure of sensitivity of the. For example, unselective protection operation during a medium voltage network fault will cause an outage for an unnecessarily large number of consumers. Relay protection is essential to ensure the stability, reliability, and safety of electrical power systems.

Read More
Analysis of the Current Status of Optical Cable Network Construction

Analysis of the Current Status of Optical Cable Network Construction

In line with CRU's recent Optical Fibre and Cable reports, major themes continue to dominate the narrative in the US market, including fibre policy and the timeline and implementation of the Broadband Equity, Access and Deployment (BEAD) Program, fibre cable deployments. The nationwide fibre rollout is crucial for Germany's competitiveness and digital progress. In mid-2024, only 23 percent of households were connected to the fibre network (homes connected), and only 11 percent had booked a fibre connection. 5 billion by 2030, and demand is shifting fast as data centers take 35% of fiber demand in 2023.

Read More
The most popular passive optical network

The most popular passive optical network

For TDM-PON, a passive optical splitter is used in the optical distribution network. In the upstream direction, each ONU (optical network units) or ONT (optical network terminal) burst transmits for an assigned time-slot (multiplexed in the time domain). It significantly improved upon BPON by adopting a more efficient protocol stack and enabling higher bandwidth. For a deep-dive analysis with in-depth forecasts, download the Passive Optical Network Market by Technology, Application, End User, Component, Deployment - Global Forecast to 2030 report. With the proliferation of bandwidth-intensive applications, such as streaming services, online gaming, and. 5 Gbps to cutting-edge 50G-PON implementations in 2025, with 100G Coherent PON (CPON) technologies emerging as the next frontier for ultra-high-speed broadband delivery.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales)

+27 21 850 1234

🇪🇺

EU Manufacturing Center

+34 936 214 587

📍

Headquarters (Spain)

Avinguda de la Garriga 23, 08830 Sant Boi de Llobregat, Barcelona, Spain